After the optical module data rate, the development
of optical module form factor, the market there are a variety of optical
modules and a variety of packages, then QSFP28 optical
module now appears, it has some advantages that can help become the
mainstream of 100G optical networks. Below, we will introduce to everyone what
is QSFP28 optical module and what are the advantages of QSFP28 optical module.
What Is QSFP28 Optical Module?
First, let's look first: What is QSFP28
optical module. Generally speaking, the optical module form factor refers to
the optical module shape, with the progress of science and technology, optical
module form factor is a step by step evolution, the volume is gradually smaller,
of course, not only the appearance of the change in the rate, power
consumption, distance , costs, etc. are also constantly moving forward.
Currently 100G optical modules have several
main form factors, including: QSFP28 optical module, CFP optical module, CFP2
optical module, CFP4 optical module, these kinds of encapsulated optical
modules all belong to 100G, of which the QSFP28 optical module is a mainstream
100G optical module on the current market.
The post will compare 100G QSFP28 optical
module and other 100G optical modules in terms of port density, power
consumption, and cost respectively.
What Are the Advantages of QSFP28 Optical
Module?
1. Port Density
The first generation of 100G optical
modules was a very large CFP optical module, and then CFP2 and CFP4 optical
modules were launched, among which CFP4 optical module was the latest
generation of 100G optical modules and had a width of only 1/4 of the CFP
optical modules. However, the form factor of 100G QSFP28 optical module is
smaller than the CFP4 optical module, which means the 100G QSFP28 optical
module has a higher port density on the switch.
2. Power Consumption
The power consumption of 100G QSFP28
optical module is usually lower than 3.5W while that of other 100G optical
modules is usually between 6W and 24W. From this, 100G QSFP28 optical modules
have much lower power consumption than other 100G optical modules.
3. Cost
Now the data center is mainly 10G network
architecture, in which the interconnection solution is mainly 10GBASE-SR
optical module and duplex LC multimode fiber jumper. If the existing 10G
network architecture can be directly upgraded to 40 / 100G networks, it will
save a lot of time and cost.
Although 100G QSFP28 optical modules have
many advantages, it is only one of many solutions for 100G network. For data
centers and server rooms, suit is best. Therefore, other 100G optical modules
also have a place in the 100G network. Gigalight thinks that 100G QSFP28
optical module series, like 100G QSFP28 SR4, 100G QSFP28 LR4, 100G QSFP28 CWDM4 and
100G QSFP28 PSM4, have brought a new solution for 100G applications that will
promote the faster development of 100G.